金堂污泥處置廠
更新時(shí)間:2025-11-21 09:50:32 字號(hào):T|T
項(xiàng)目情況

干化煙氣采用“急冷+活性炭噴射+布袋除塵+SCR+煙氣冷卻+堿液脫酸+UV光氧催化除臭+噴淋除臭+活性炭+除白煙”煙氣凈化系統(tǒng)處理后排放,此工藝運(yùn)行效果不太理想,投訴多。
技改方案為:堿液脫酸、噴淋除臭兩個(gè)塔利舊,內(nèi)部結(jié)構(gòu)優(yōu)化,噴淋介質(zhì)更換為吉可益溶液。

 

治理效果

二級(jí)塔藥劑濃度為0.4%、0.3%,10天添加一次藥劑,每月?lián)Q水一次。技改后,排放臭氣濃度降低至800(無(wú)量綱)左右,運(yùn)行4個(gè)月******的一次投訴是因?yàn)閲娏芩Q水沒(méi)有停氣所致。

Jintang Sludge Disposal Plant

Project Details

The drying flue gas is treated through a purification system comprising "quenching + activated carbon injection + baghouse dust removal + SCR + flue gas cooling + alkaline deacidification + UV photolytic oxidation deodorization + spray tower deodorization + activated carbon adsorption + white smoke elimination" before emission. However, the operational effectiveness of this process has been unsatisfactory, resulting in numerous complaints.

The technical retrofit plan involved retaining and optimizing the internal structures of the alkaline deacidification and spray deodorization towers, while replacing the spraying medium with Jikeyi solution.

Treatment Results

The chemical concentration in the secondary tower is maintained at 0.4% and 0.3%, with reagent replenished every 10 days and water replaced monthly. Following the retrofit, the emitted odor concentration has been reduced to approximately 800 (dimensionless). The only complaint received over four months of operation was due to the failure to halt gas flow during a water change in the spray tower.